Oxygen saturation and heart rate during delivery room resuscitation of infants <30 weeks’ gestation with air or 100% oxygen

143Citations signalées — pas une note de qualité
4Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: Because of concerns about harmful effects of 100% oxygen on newborn infants, air has started to be used for resuscitation in the delivery room. OBJECTIVE: To describe changes in preductal oxygen saturation (Spo(2)) and heart rate (HR) in the first 10 min after birth in very preterm infants initially resuscitated with 100% oxygen (OX(100)) or air (OX(21)). PATIENTS AND METHODS: In July 2006, policy changed from using 100% oxygen to air. Observations of Spo(2) and HR before and after the change were recorded whenever a member of the research team was available to attend the birth. RESULTS: There were 20 infants in the OX(100) group and 106 in the OX(21) group. In the OX(100) group, Spo(2) had risen to a median of 84% after 2 min and 94% by 5 min. In the OX(21) group, median Spo(2) was 31% at 2 min and 54% at 5 min. In the OX(21) group, 92% received supplemental oxygen at a median of 5 min; the Spo(2) rose to a median of 81% by 6 min. In the first 10 min after birth, 80% and 55% of infants in the OX(100) and OX(21) groups, respectively, had an Spo(2) > or =95%. Increases in HR over the first 10 min were very similar in the two groups. CONCLUSIONS: Most very preterm infants received supplemental oxygen if air was used for the initial resuscitation. In these infants, the use of backup 100% oxygen and titration against Spo(2) resulted in a similar course to "normal" term and preterm infants. Of the infants resuscitated with 100% oxygen, 80% had Spo(2) > or =95% during the first 10 min. The HR changes in the two groups were very similar.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
Oxygen saturation and heart rate during delivery room resuscitation of infants &lt;30 weeks’ gestation with air or 100% oxygen
Date Crossref
14/08/2008
Éditeur
BMJ
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Neonatal Respiratory Health ResearchNeonatal and fetal brain pathologyPreterm Birth and Chorioamnionitis

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.