Delayed Sciatic Palsy after Total Hip Replacement
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
A 33-year-old woman with a 22-year history of juvenile rheumatoid arthritis developed right lower extremity sciatica 32 months after total hip arthroplasty. Physical examination and electromyography localized the abnormality to the sciatic nerve proximal to the midthigh level, involving the branch to the short head of the biceps femoris muscle. At surgical exploration, a sharp spur of methyl methacrylate, used to cement the acetabular prosthesis to the acetabulum, was found to have eroded through the lateral half of the sciatic nerve. The sciatica was relieved by neurolysis. The etiology of sciatic neuropathy after total hip replacement is reviewed.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Delayed Sciatic Palsy after Total Hip Replacement
- Date Crossref
- 01/07/1981
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.