Clinical Investigations Dosimetric Improvements in Balloon Based Brachytherapy Using the Contura Multi-Lumen Balloon (MLB) Catheter to Deliver Accelerated Partial Breast Irradiation

4Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Purpose: Preliminary dosimetric findings in patients managed with the Contura ® Multi-Lumen Balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) on a multi-institutional phase IV registry trial were reviewed.Material and methods: CT-based 3D planning with dose optimization was performed for all patients.For the study, new ideal dosimetric goals were developed: 1) ≥ 95% of the prescribed dose (PD) covering ≥ 90% of the target volume (TV), 2) a maximum skin dose ≤ 125% of the PD, 3) maximum rib dose ≤ 145% of the PD, and 4) the V150 ≤ 50 cc and V200 ≤ 10 cc.The frequency of concurrently achieving these dosimetric goals using the Contura ® MLB was investigated.Results: 194 cases were evaluable.Employing the MLB, all ideal dosimetric criteria were achieved in 76% of cases.Evaluating dosimetric criteria separately, 90% and 89% of cases met the new ideal skin and rib dose criteria, respectively.In 96%, ideal TV coverage goals were achieved and in 96%, dose homogeneity criteria (V150 and V200) were met.For skin spacing ≥ 5-7 mm, the median skin dose was 121% of the PD and when < 5 mm, the median skin dose was 124.4%.For rib distancees < 5 mm, the median rib dose was reduced to 136.4% of the PD.For skin spacing < 7 mm and distance to rib < 5 mm, the median skin and rib doses were concurrently limited to 121% and 142.8% of the PD, respectively. Conclusions:The Contura ® MLB catheter provides potential improvements in dosimetric capabilities (i.e., reduced skin and rib doses and improved TV coverage) in many clinical scenarios.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Clinical Investigations Dosimetric Improvements in Balloon Based Brachytherapy Using the Contura Multi-Lumen Balloon (MLB) Catheter to Deliver Accelerated Partial Breast Irradiation
Date Crossref
01/01/2010
Éditeur
Termedia Sp. z.o.o.
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Breast Cancer Treatment StudiesAdvanced Radiotherapy TechniquesBreast Implant and Reconstruction

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.