Arterial Pressure-Flow Relationship in Patients Undergoing Cardiopulmonary Bypass
Rattachement africain : cl. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
We determined the arterial pressure-flow relationship experimentally by means of step changes of blood flow in 30 adult patients undergoing cardiopulmonary bypass (CPB). Anesthesia technique was uniform. CPB was nonpulsatile; hypothermia to 25-28 degrees C, and hemodilution to 18%-25% hematocrit were used. During stable bypass, mean arterial pressure was recorded first with blood flow 2.2 L.min-1.m-2. Flow was then increased to 2.9 L.min-1.m-2 for 10 s and reverted to baseline for 1 min. Then it was decreased to 1.45 L.min-1.m-2 for 10 s, and reverted to baseline for 1 min. Subsequently, it was decreased to 0.73 L.min-1.m-2 for 10 s and then reverted to baseline. Similar sets of measurements were repeated after 0.25 mg of phenylephrine and once the patient was rewarmed. The pressure-flow function was individually determined by regression, and the critical pressure estimated by extrapolation to zero flow. All patients had zero-flow critical pressure during hypothermia, with a mean value of 21.8 +/- 6.4 mm Hg (range 8.8-38.9). It increased after 0.25 mg phenylephrine to 25.4 +/- 7.2 mm Hg (range 12.2-43.9, P < 0.001). During normothermia, critical pressure was 21.2 +/- 5 mm Hg (range 13.4-30.9), not significantly different from hypothermia. During hypothermia, the slope of the pressure-flow function (i.e., resistance) was 14.9 +/- 3.5 mm Hg.L-1.min-1.m-2 (range 7.6-22.1). It increased significantly (P < 0.001) after phenylephrine, to 19.7 +/- 6.2 mm Hg.L-1.min-1.m-2 (range 11.4-40.5), and returned to 15.4 +/- 3.4 mm Hg.L-1.min-1.m-2 (range 10.1-24.2) during normothermic bypass. Systemic vascular resistance appeared to vary reciprocally with blood flow, although this finding may represent a mathematical artifact, which can be avoided by using zero-flow critical pressure in the vascular resistance equation.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Arterial Pressure-Flow Relationship in Patients Undergoing Cardiopulmonary Bypass
- Date Crossref
- 01/05/1997
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Pontificia Universidad Católica de Chile pays non établi dans la noticeUniversité ou école supérieure
-
Catholic University of Chile School of Medicine Department of Anesthesiology pays non établi dans la noticeUniversité ou école supérieure
Pontificia Universidad Católica de Chile et Department of Anesthesiology — Catholic University of Chile School of Medicine.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.