Is Surface ECG a Useful Surrogate for Subcutaneous ECG?

31Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : us, nl. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Surface electrocardiograms (ECGs) have been used as surrogates for subcutaneous ECGs to optimize and evaluate subcutaneous devices, but differences between surface and subcutaneous ECGs remain poorly understood. This study evaluated the correspondence between surface and subcutaneous ECGs in Reveal Plus (Medtronic Inc., Minneapolis, MN, USA) patients during various maneuvers. METHODS: Surface electrodes were placed over the Reveal electrodes of 48 subjects (23 men, age 60 +/- 14.3 years, body mass index 27 +/- 4.9 kg/m(2), implant time 45 +/- 29 weeks). Surface and subcutaneous ECGs were recorded simultaneously for 30 seconds during rest, isometric myopotential noise (pushing palms together), and artifact-inducing maneuvers (repetitive displacement of device, chest thumping on device, arm flaps, handshake, hallwalk). RESULTS: During rest, subcutaneous and surface ECGs were highly correlated (R = 0.96), had similar R-wave amplitude (487 +/- 40 vs 507 +/- 49 microV, NS), and signal-to-noise ratio (SNR) (13.4 +/- 0.8 vs 13.5 +/- 0.7, NS). During myopotential noise, subcutaneous and surface ECGs were highly correlated (R = 0.91) and had similar SNR (10.0 +/- 0.6 vs 9.7 +/- 0.6, NS). During artifact-inducing maneuvers, subcutaneous and surface ECGs were less correlated (R = 0.82 displacement, 0.84 chest thumping, 0.93 arm flaps, 0.90 handshake, 0.92 hallwalk) with subcutaneous SNR significantly higher than surface (11.4 +/- 0.7 vs 9.9 +/- 0.7 displacement, 11.1 +/- 0.6 vs 8.4 +/- 0.6 chest thumping, 11.5 +/- 0.4 vs 10.3 +/- 0.5 arm flaps, 9.5 +/- 0.4 vs 8.4 +/- 0.4 handshake, 12.0 +/- 0.4 vs 10.0 +/- 0.4 hallwalk, P < 0.05). CONCLUSION: Surface ECGs are adequate surrogates for subcutaneous ECGs in situations free from motion artifacts but not in situations involving movement of the device, surface electrodes, or recording equipment. During artifact-inducing maneuvers, subcutaneous ECGs are of higher quality and less susceptible to artifacts than surface ECGs.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Is Surface ECG a Useful Surrogate for Subcutaneous ECG?
Date Crossref
01/02/2010
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

ECG Monitoring and AnalysisCardiac electrophysiology and arrhythmiasCardiac pacing and defibrillation studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.