Aller au contenu principal
2012 article

Do the Traditional and Modified Latarjet Techniques Produce Equivalent Reconstruction Stability and Strength?

56Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : ca, ch. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: The Latarjet procedure has been described as a reconstructive option for instability associated with substantial glenoid bone defects. A modification, termed the Congruent-Arc, is thought to improve glenoid reconstruction through better articular congruency and greater bone reconstitution. The strengths of these techniques, however, have not been reported. Purpose/ HYPOTHESIS: To compare the fixation stability, strength, glenoid vault load transfer, and joint contact between the Classic and Congruent-Arc techniques. The authors hypothesized that the Classic Latarjet would exhibit inferior joint contact characteristics while having greater stability and strength and more normal glenoid vault strain. STUDY DESIGN: Controlled laboratory study. METHODS: Sixteen shoulder specimens (8 pairs) were tested by loading the glenohumeral joint with the glenoid intact, following creation of a 25% anterior bone defect, and after random assignment to the Classic or Congruent-Arc Latarjet techniques. Specimens were mounted to a testing apparatus that allowed concentric, centralized loading and loading 30° anterior on the glenoid rim. Cyclic loading (100 cycles at 1 Hz) was applied with a staircase protocol (50, 100, 150, and 200 N). Graft interface displacement and glenoid load transfer, quantified in terms of strain, were recorded during loading. Contact was quantified during 50-N loading using a thin pressure sensor. After cyclic loading, specimens were loaded to failure, defined as 5 mm of graft interface displacement. RESULTS: The 30° loading ≥100 N resulted in significantly greater graft displacement (P < .004) in the Congruent-Arc group as compared with the Classic (mean displacement range, 0.9-2.6 vs 0.1-0.5 mm, respectively). Failure testing yielded a significantly (P = .010) greater ultimate strength for the Classic (557 N) as compared with the Congruent-Arc (392 N). Load-transfer measurements demonstrated that neither technique's glenoid vault strain values significantly differed from intact (P ≥ .076). Both techniques resulted in contact areas significantly less than intact (P < .035); however, the Congruent-Arc trended toward better contact characteristics (P = .074). CONCLUSION: The Congruent-Arc results in significantly poorer fixation stability as compared with the Classic technique but did more closely reproduce intact joint contact, which may yield more favorable long-term outcomes. CLINICAL RELEVANCE: Care must be taken in balancing the consideration of initial fixation stability and joint contact for the Congruent-Arc and Classic Latarjet, as these factors have opposing implications for each of the 2 reconstructions' outcomes.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Do the Traditional and Modified Latarjet Techniques Produce Equivalent Reconstruction Stability and Strength?
Date Crossref
28/09/2012
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • St Joseph's Health Centre pays non établi dans la notice
    Établissement de santé
  • University of Zurich pays non établi dans la notice
    Université ou école supérieure
  • Universitätsklinik Balgrist pays non établi dans la notice
    Établissement de santé
  • Bioengineering Research Laboratory pays non établi dans la notice
    Structure de recherche
  • Balgrist University Hospital pays non établi dans la notice
    Université ou école supérieure

St Joseph's Health Centre, University of Zurich et Universitätsklinik Balgrist, avec 2 autres affiliations.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Shoulder Injury and TreatmentShoulder and Clavicle InjuriesTrauma Management and Diagnosis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.