Aller au contenu principal
Accès ouvert déclaré 2005 article

Dynamic assessment of high-resolution MRI with multi-planar reconstruction increases the yield of lesion detection in patients with partial epilepsy

4Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : br. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Objective: To investigate the presence and type of lesions associated with partial epilepsies by routine high resolution MRI and multi-planar reconstruction (MPR) and correlate the MRI abnormalities with semiology and EEG findings. Methods: We studied 100 consecutive patients followed in the epilepsy clinic of our Hospital with partial epilepsy who underwent MRI investigation. The MRI protocol included 6 mm sagittal T1-weighted, 3-4 mm axial T1 and T2-weighted, 3 mm coronal T1 inversion recovery and T2-weighted images that were printed on a radiographic film for routine analysis. In addition, all patients had a volume T1-gradient echo acquisition with isotropic voxels (1-1.5 mm) for multiplanar reconstruction (MPR). The MRIs were examined in two different occasions: first using only the images printed on films, without volume T1-gradiente echo acquisition and in a second occasion in a computer workstation when all the available images and MPR were analyzed blindly to the clinical information. The clinical and EEG findings were tabulated independently, and results were compared using Chi-square of Fisher exact test when appropriate. Results: The patients were divided into 10 groups according to their etiological classification (structural lesions) established by MRI. Mesial temporal sclerosis (MTS) was the largest group (40%). There were 65 women and 35 men. Mean age was 23.9 (± 5.7) years and mean age of onset of recurrent seizures was 9.9 (± 0.8) years. The most frequent risk factors were family history of seizures (23%), head trauma (10%),peri-natal anoxia (5%) and infection (9%). High resolution MRI including thin coronal slices, in addition to a “dynamic” analysis in a workstation with MPR, allowed a significant improvement in lesion detection compared to the traditional analysis with radiographic films (94% versus 80%) (p < 0.05). The lesions previously undetected were focal cortical dysplasia and subtle MTS. There was a good concordance between MRI lesions and clinical and EEG findings. Conclusion: High resolution MRI including thin coronal slices, in addition to a “dynamic” analysis in a workstation with MPR allowed a significative improvement in lesion detection compared to the traditional analysis with radiographic films (94% versus 80%). Patients with partial epilepsy and “normal” MRI need to be investigated further with thin slices and post-processing techniques using volume acquisitions that allow adequate multiplanar re-slicing.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Dynamic assessment of high-resolution MRI with multi-planar reconstruction increases the yield of lesion detection in patients with partial epilepsy
Date Crossref
01/01/2005
Éditeur
FapUNIFESP (SciELO)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Epilepsy research and treatmentFetal and Pediatric Neurological DisordersInfectious Encephalopathies and Encephalitis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.