Aller au contenu principal
2015 article

Permanent pacing after transcatheter aortic valve implantation of a CoreValve prosthesis as determined by electrocardiographic and electrophysiological predictors: a single-centre experience

41Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : gr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

AIM: The most frequent conduction complications with transcatheter aortic valve implantation (TAVI) are complete atrioventricular (AV) block and new bundle branch block (BB). The purpose of this study was to assess clinical, electrocardiographic, and electrophysiological predictors of conduction abnormalities in patients (pts) undergoing TAVI with the CoreValve prosthesis. The secondary end points were the long-term rhythm follow-up and the recovery of conduction. METHODS AND RESULTS: Forty-five consecutive pts with severe aortic stenosis, New York Heart Association II/III, and normal or slightly impaired left ventricular function who underwent CoreValve transcatheter implantation were randomized 2:1 to electrocardiographic and electrocardiographic plus electrophysiological evaluations. Pacemakers were implanted in pts with complete AV block. Follow-up was performed at 1, 6, 12, and 24 months. Conduction was affected in the total group of pts undergoing TAVI. The PR lengthened compared with the baseline but did not exceed the normal cut-off of 200 ms, and the QRS widened, basically due to new left bundle branch blocks (LBBBs). Within 1 month of follow-up, 10 pts (22%) developed complete AV block (9 peri-procedurally-20%) and 15 pts (33%) developed a new bundle BB, with LBBBs being the most common (14-31%). In the 30 pts who underwent an electrophysiological study, analysis showed that prolonged HV intervals were prognostic for pacemaker implantation. Follow-up in the total study group revealed that only 4 of the 10 (9%) initial implantations remained completely pacemaker dependent. CONCLUSION: Conduction was affected in all pts undergoing TAVI, but serious complications that required permanent pacing generally occurred in pts with pre-existing conduction abnormalities.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Permanent pacing after transcatheter aortic valve implantation of a CoreValve prosthesis as determined by electrocardiographic and electrophysiological predictors: a single-centre experience
Date Crossref
09/06/2015
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Valve Diseases and TreatmentsCardiovascular Function and Risk FactorsCardiac pacing and defibrillation studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.