Aller au contenu principal
2013 article

Procedural Effectiveness of a Novel 1.20 mm Diameter Angioplasty Catheter: Clinical and Angiographic Outcomes

2Citations signalées, ce qui n’est pas une note de qualité
8Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVE: To evaluate clinical and angiographic outcomes using a 1.20 mm diameter angioplasty catheter as part of a predilation strategy for coronary lesion treatment. BACKGROUND: Development of an angioplasty catheter with low crossing profile and small balloon diameter represents an opportunity to facilitate percutaneous revascularization of complex coronary disease. METHODS: Clinical and angiographic outcomes were evaluated following a predilation treatment strategy using a low profile, 1.20 mm angioplasty catheter. The primary end-point of procedural success was defined as successful device delivery, performance and lesion treatment without occurrence of perforation, flow-limiting dissection, reduction in baseline TIMI grade, or clinically significant arrhythmias, and with final achievement of TIMI 3 flow. In-hospital major adverse events were also determined. RESULTS: Among 71 patients (83 lesions), angiographic characteristics included: de novo lesion, 75.9%; saphenous vein graft 9.6%; lesion length (mean ± standard deviation), 12.27 ± 5.96 mm; reference vessel diameter, 2.61 ± 0.57 mm; lesion classification B2/C, 59.0%; baseline TIMI 0/1 flow, 4.8%. Procedural success was achieved for 98.5% (66/67) of patients. Catheter delivery to the target lesion was achieved in all patients, and the rate of device success with luminal improvement after predilation was 96.2% (75/78). No acute procedural complications were observed, and in-hospital target lesion failure occurred in 6 patients (8.5%) related to peri-procedural non-Q wave myocardial infarction. CONCLUSIONS: Coronary lesion predilation with a low profile, 1.20 mm angioplasty catheter is associated with favorable procedural safety and efficacy and may represent an effective treatment for complex coronary anatomy.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Procedural Effectiveness of a Novel 1.20 mm Diameter Angioplasty Catheter: Clinical and Angiographic Outcomes
Date Crossref
31/01/2013
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Coronary Interventions and DiagnosticsVascular Procedures and ComplicationsCardiac and Coronary Surgery Techniques

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.