Scanning electron microscopy of bacteria adherent to intravascular catheters

131Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

Scanning electron microscopy was used to assess the morphological features of coagulase-negative staphylococci adherent to polyvinylchloride intravascular catheter specimens. Clinical specimens were obtained by using patient catheters from which coagulase-negative staphylococci (greater than or equal to 15 colonies per catheter) grew on semiquantitative blood agar roll cultures. In vitro specimens were prepared by a previously published technique in which sterile polyvinylchloride catheters were immersed in 10(6) CFU of coagulase-negative staphylococci per ml suspended in phosphate-buffered saline. Unused sterile polyvinylchloride catheters were also examined. Scanning electron microscopy of unused sterile polyvinylchloride catheters demonstrated multiple linear surface irregularities. Scanning electron microscopy of infected patient catheters showed a diffuse amorphous material covering the entire surface and the presence of bacteria which appeared anchored to that surface by several different means. These included a slime layer, "foot" processes, and lodgement in surface irregularities. Scanning electron microscopy of in vitro specimens demonstrated no background surface coating, but it did show attachment of cocci to the surface by the same mechanisms as described for clinical specimens. These observations of similar means of attachment in clinical and in vitro specimens suggest that intrinsic catheter surface properties, bacterial surface features, and perhaps coating with host substances may all play a role in bacterial attachment to intravascular catheters. More sophisticated analysis of these interactions may clarify mechanisms of pathogenesis.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Scanning electron microscopy of bacteria adherent to intravascular catheters
Date Crossref
01/09/1984
Éditeur
American Society for Microbiology
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les sujets associés

Central Venous Catheters and HemodialysisAntimicrobial Resistance in StaphylococcusStreptococcal Infections and Treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.