Aller au contenu principal
2014 article

The impact of individual variation analysis on myocardial perfusion imaging utilization within a hospitalist group

4Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Increased recognition of ionizing radiation risks has placed an emphasis on the appropriate use of myocardial perfusion imaging (MPI). Hospitalists frequently order MPI in the evaluation of chest pain and are thus at the forefront of its inpatient utilization. METHODS: We collected baseline figures for a group MPI rate (March 2010-February 2011) as well as individual MPI rates for hospitalists caring for cardiac floor patients at a community teaching hospital. We performed a 2-part intervention; we presented the individual MPI rate data back to the hospitalist division and carried out longitudinal educational efforts on MPI appropriateness criteria. We then calculated the group MPI utilization rate for 3 postintervention periods (March 2011-February 2012, March 2012-February 2013, and March 2013-February 2014) and the MPI rate for the subgroup of cardiac floor patients. Finally, we calculated the percentage of inappropriately performed stress tests before and after our intervention. RESULTS: Group MPI rate declined from 6.1% to 5.0% in the first year after our intervention (P = 0.009); a decrease was maintained a year later-MPI rate 4.9% (P = 0.004)-and became even more pronounced 2 years later-MPI rate 3.9% (P < 0.0001). The MPI rate for the subgroup of patients on the cardiac floor similarly decreased from 8.0% to 6.7% (P = 0.039). Finally, we report a particularly encouraging and significant trend of a 46% postintervention decrease (from 16.5% to 9%, P = 0.034) in the proportion of inappropriate stress tests ordered. CONCLUSIONS: Analyzing individual ordering rates and combining them with educational efforts was an effective strategy for impacting MPI utilization in the hospitalist group studied.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
The impact of individual variation analysis on myocardial perfusion imaging utilization within a hospitalist group
Date Crossref
28/11/2014
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Radiation Dose and ImagingCardiac Imaging and DiagnosticsUltrasound in Clinical Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.