The Use of a Multichannel Analyzer to Investigate Effects of Experimental Factors on Gross-Counting Gamma and Neutron Detectors

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Radiation detection technology is invaluable to many fields of study in identifying nuclear materials. However, many detectors use gross-counting methods that give only a relative count rate. Without a spectrum (information on counts over time vs energy), it can be more difficult to discern if an alarm is false, innocent, or real. In particular, we would like to understand better the effect of experimental factors (i.e., external conditions and equipment parameters) on detector data, with possible implications for false alarms. To more thoroughly characterize detector technology, a multichannel analyzer (MCA) was used to record spectra from neutron (helium-3 tubes) and gamma (photomultiplier tubes) gross-counting detectors. Several factors could affect the signal-to-noise ratio of sources. For example, we examined the effects of neutron detector high voltage setting on the appearance of a californium-252 spectrum, the effect of discriminator values on integrated counts in neutron detection, and the effect of gain changes on the gamma spectra from several sources. Possible implications of ambient temperature of the experiment on the data collected will be discussed. The input impedance of the MCA must be considered to ensure that data are not affected by the measurement itself. Moreover, a calibration on the MCA was performed to verify the conversion of a MCA channel number to a voltage. In summary, the series of source spectra collected on an MCA with a variety of experimental conditions allow us to understand factors that affect data better, and assure us that gross-counting neutron and gamma detectors will have minimal false alarms.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

Aucun DOI disponible pour le contrôle Crossref.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Nuclear Physics and ApplicationsRadiation Detection and Scintillator TechnologiesNuclear reactor physics and engineering

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.