Aller au contenu principal
2013 article

Transseptal antegrade transcatheter aortic valve replacement for patients with no other access approach—A contemporary experience

30Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : us, jp. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVE: To assess the feasibility and outcomes in patients undergoing transvenous transseptal (TS) transcatheter aortic valve replacement (TAVR). BACKGROUND: TS approach for TAVR was abandoned in favor of retrograde transfemoral, transaortic, or transapical approaches. TS TAVR may still be warranted in patients for whom no other approach is feasible. METHODS: Observational consecutive case series at a single center, to evaluate technical outcomes in inoperable patients with aortic stenosis who had contraindications for other approaches and who underwent TAVR via a transvenous TS antegrade approach using the Edwards-Sapien (ES) valve. RESULTS: Over a 4-month period, 9 patients underwent TS TAVR with 26 mm (n = 4) and 23 mm (n = 5) ES valves. Mean age was 84.5 ± 6.6 years and Society of Thoracic Surgeons predicted risk of mortality was 7.8 ± 2.8%. Specific contraindications for other access included iliofemoral arterial diameter <7 mm in 9 (100%), porcelain aorta in 6 (66%) patients, multiple (≥2) sternotomies in 2 (22%) patients, severe pulmonary disease in 3 (33%), extreme frailty in 1 (11%), spinal stenosis with impaired ability to rehabilitate postsurgery in 1 (11%) and apical left ventricular thrombus in 1 (11%) patient. Antegrade deployment of the ES prosthetic valve was technically feasible in 8 patients. Major bleeding occurred in 4 patients, two patients suffered acute kidney injury without need for dialysis and one patient required a permanent pacemaker. The median (25th, 75th percentiles) fluoroscopy time was 49 (34, 81) minutes and contrast volume was 150 (120, 225) ml. No patient had hemodynamically significant post-TAVR aortic insufficiency nor damage to the mitral valve. At 6 months follow-up, there were no cerebrovascular events or rehospitalizations and mean NYHA Class improved from 3.4 to 1.7. CONCLUSIONS: The antegrade TS approach to TAVR is a technically feasible option for "no-access" patients. Prospective assessment of the safety and efficacy of this approach in the current era warrants further study.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Transseptal antegrade transcatheter aortic valve replacement for patients with no other access approach—A contemporary experience
Date Crossref
03/07/2013
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Valve Diseases and TreatmentsAortic Disease and Treatment ApproachesInfective Endocarditis Diagnosis and Management

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.