Aller au contenu principal
2013 article

Tricuspid Annular Plane Systolic Excursion for the Assessment of Ventricular Function in Adults Operated on with Mustard Procedure for Complete Transposition of the Great Arteries

29Citations signalées — pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: In adult patients with d-transposition of the great arteries after atrial switch operation, dysfunction of the systemic right ventricle (RV) is a well-known complication. Echocardiographic variables may provide adequate estimation of subpulmonary RV function, but their applicability to the subaortic RV is not straightforward. We evaluate the concordance between tricuspid annular plane systolic excursion (TAPSE) and magnetic resonance imaging-derived ejection fraction of the RV (MRI-RVEF) in these patients. METHODS: Patients were recruited from those evaluated at the adult congenital clinic of our department between 2010 and 2012. All patients who had an echocardiographic assessment within 6 months of their MRI examination were selected. Patients clinically unstable, not in sinus rhythm, with a prosthetic systemic atrioventricular valve, permanent pacemaker, or more than moderate systemic atrioventricular valve regurgitation were excluded. RESULTS: Eighteen Mustard-operated patients aged 22 ± 3.7 years were studied. The mean values of TAPSE and RVEF were 13.22 ± 1.7 mm and 49.7 ± 6%, respectively. TAPSE and RVEF were normal in 1 (5.5%) and 10 (55.5%) patients, respectively. Seventeen (94.4%) patients showed reduced TAPSE (12.9 ± 1.3 mm): RVEF was reduced in eight (47%) of these subjects, and normal in nine (53%). In patients with normal RVEF, both the MRI-RV end-diastolic and the MRI-RV end-systolic volumes were significantly lower than in patients with reduced RVEF. There were no other statistically significant differences between these patients. No correlation was found between TAPSE and both the MRI-RV end-diastolic and the end-systolic volumes. Globally, agreement between TAPSE and RVEF was slight (K = 0.09 ± 0.089). CONCLUSIONS: Our results indicate that in these patients TAPSE is not a useful measure of RV function.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Tricuspid Annular Plane Systolic Excursion for the Assessment of Ventricular Function in Adults Operated on with Mustard Procedure for Complete Transposition of the Great Arteries
Date Crossref
08/09/2013
Éditeur
Computers, Materials and Continua (Tech Science Press)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Congenital Heart Disease StudiesPulmonary Hypertension Research and TreatmentsCardiac Valve Diseases and Treatments

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.