Efficacy of Tuned Waveforms Based on Different Membrane Time Constants on Defibrillation Thresholds: Primary Results from the POWER Trial

11Citations signalées, ce qui n’est pas une note de qualité
7Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: The efficacy of tuned defibrillation waveforms versus the nominal fixed-tilt waveform has been previously studied. However, the optimal membrane time constant for tuning was not known. The POWER (Pulsewidth Optimized Waveform Evaluation tRial) trial was designed to determine the optimal membrane time constant for programming "tuned" biphasic waveforms. METHODS: This acute, multicenter study included 121 implantable cardioverter-defibrillator/cardiac resynchronization therapy defibrillator patients who were randomized at implant to any two of the three membrane time constant waveforms (2.5, 3.5, and 4.5 ms). Fixed pulse widths were programmed using the measured high voltage shock impedance. The defibrillation threshold (DFT) estimates were obtained using a hybrid protocol starting with an upper limit of vulnerability estimate followed by a step-up/step-down ventricular fibrillation induction process. RESULTS: DFT voltage was significantly lower using 3.5- and 4.5-ms waveforms as compared to the 2.5-ms waveform (P = 0.004 and 0.035, respectively). DFT voltage with both 3.5- and 4.5-ms waveforms was ≤ that obtained with the 2.5-ms waveform in 78.5% of the cases. The mean difference in DFT voltage using the 3.5-ms waveform and the 4.5-ms waveform was not significant (P = 0.4). However, the 3.5-ms waveform gave a lower DFT than the 4.5-ms waveform in 19 patients although the reverse was true in only nine (P = 0.02 not significant for multiple comparisons). CONCLUSIONS: The use of a 3.5- or 4.5-ms time constant-based waveforms had lower DFTs when compared to the 2.5-ms waveform. This study suggests that the first defibrillation attempt at implantation should be with 3.5- or 4.5-ms time constant-based waveforms. The 3.5-ms-based waveform trended toward the best choice.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Efficacy of Tuned Waveforms Based on Different Membrane Time Constants on Defibrillation Thresholds: Primary Results from the POWER Trial
Date Crossref
20/08/2012
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac pacing and defibrillation studiesCardiac electrophysiology and arrhythmiasCardiac Arrest and Resuscitation

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.