Direct measurements of the lifetime of medium-heavy hypernuclei
X. Qiu, Liangyu Tang, C. Chen, A. Margaryan et autres
cn, us, am, de, hr, jp (code pays fourni par la source)
Informations fournies par OpenAlex. Research Africa ne déduit ni nationalité, ni poste, ni coordonnées personnelles.
X. Qiu, Liangyu Tang, C. Chen, A. Margaryan et autres
cn, us, am, de, hr, jp (code pays fourni par la source)
T. Gogami, C. Chen, Daisuke Kawama, Patrick Achenbach et autres
The missing mass spectroscopy of the $_{\mathrm{\ensuremath{\Lambda}}}^{7}\mathrm{He}$ hypernucleus was performed using the $^{7}\mathrm{Li}(e,{e}^{\ensuremath{'}}{K}^{+})\phantom{\rule{0.16em}{0ex}}_{\mathrm{\ensuremath{\Lambda}}}^{7}\mathrm{He}$ reaction at the Thomas Jefferson National Accelerator Facility Hall C. The $\mathrm{\ensuremath{\Lambda}}$-binding energy of the ground-state ($1/{2}^{+}$) was determined with a smaller error than that of the previous measurement, …
jp, us, de, hr, am, it, cn, pr (code pays fourni par la source)
T. Gogami, C. Chen, Daisuke Kawama, Patrick Achenbach et autres
The missing mass spectroscopy of the $^{7}_{\Lambda}$He hypernucleus was performed, using the $^{7}$Li$(e,e^{\prime}K^{+})^{7}_{\Lambda}$He reaction at the Thomas Jefferson National Accelerator Facility Hall C. The $\Lambda$ binding energy of the ground state (1/2$^{+}$) was determined with a smaller error than that of the …
T. Gogami, C. Chen, Daisuke Kawama, Patrick Achenbach et autres
This new JLab measurement demonstrates the capability of the facility to determine the ground state binding energy of $\mathrm{\ensuremath{\Lambda}}$ hypernuclei. Comparison of the measured ${}_{\mathrm{\ensuremath{\Lambda}}}^{10}$Be result with that of its mirror hypernucleus is consistent with the small charge-symmetry breaking for $p$-shell $\mathrm{\ensuremath{\Lambda}}$ …
jp, us, de, hr, am, it, cn, pr (code pays fourni par la source)
T. Gogami, C. Chen, D. Kawama, Patrick Achenbach et autres
Spectroscopy of a $^{10}_Λ$Be hypernucleus was carried out at JLab Hall C using the $(e,e^{\prime}K^{+})$ reaction. A new magnetic spectrometer system (SPL+HES+HKS), specifically designed for high resolution hypernuclear spectroscopy, was used to obtain an energy spectrum with a resolution of 0.78 MeV …
T. Gogami, Patrick Achenbach, A. Ahmidouch, I. Albayrak et autres
JLab E05-115 which is an experiment for Λ hypernuclear spectroscopy with electron beams was carried out at Jefferson Lab (JLab) in 2009.In the experiment, 7 Λ He, 9 Λ Li, 10 Λ Be, 12 Λ B and 52 Λ V were measured …
jp, de, us, hr, am, it, cn, pr (code pays fourni par la source)
Liguang Tang, C. Chen, T. Gogami, Daisuke Kawama et autres
Since the pioneering experiment, E89-009 studying hypernuclear spectroscopy using the $(e,e^{\prime}K^+)$ reaction was completed, two additional experiments, E01-011 and E05-115, were performed at Jefferson Lab. These later experiments used a modified experimental design, the "tilt method", to dramatically suppress the large electromagnetic …
us, jp, hr, pr, de, am, it, cn (code pays fourni par la source)
Liangyu Tang, C. Chen, T. Gogami, Daisuke Kawama et autres
Since the pioneering experiment, E89-009 studying hypernuclear spectroscopy using the $(e,e^{\prime}K^+)$ reaction was completed, two additional experiments, E01-011 and E05-115, were performed at Jefferson Lab. These later experiments used a modified experimental design, the Tilt Method, to dramatically suppress the large electromagnetic …
T. Gogami, Patrick Achenbach, A. Ahmidouch, I. Albayrak et autres
jp, us, hr, am, it, cn, pr (code pays fourni par la source)
T. Gogami, Patrick Achenbach, A. Ahmidouch, I. Albayrak et autres
Shintaro Nakamura, A. Acha, Patrick Achenbach, A. Ahmidouch et autres
jp (code pays fourni par la source)
T. Gogami, Patrick Achenbach, A. Ahmidouch, I. Albayrak et autres
jp (code pays fourni par la source)
BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.
L'essentiel de l'actu tech du Burkina & d'Afrique, chaque semaine dans votre boîte mail.
Gratuit · sans spam · désinscription en un clic