Accès ouvert
2018
article
OpenAlex
Eric Armengaud, C. Augier, A. Benoı̂t, L. Bergé et autres
We make use of the EDELWEISS-III array of germanium bolometers to search for electron interactions at the keV scale induced by phenomena beyond the Standard Model. A 90% C.L. lower limit is set on the electron lifetime decaying to invisibles, $\ensuremath{\tau}>1.2\ifmmode\times\else\texttimes\fi{}{10}^{24}\text{ }\text{ …
fr, de, gb, ru
(code pays fourni par la source)
Accès ouvert
2018
article
OpenAlex
Q. Arnaud, Eric Armengaud, C. Augier, A. Benoı̂t et autres
The physics potential of EDELWEISS detectors for the search of low-mass weakly interacting massive particles (WIMPs) is studied. Using a data-driven background model, projected exclusion limits are computed using frequentist and multivariate analysis approaches, namely, profile likelihood and boosted decision tree. Both …
fr, de, gb, ru
(code pays fourni par la source)
Accès ouvert
2017
article
OpenAlex
Eric Armengaud, Q. Arnaud, C. Augier, A. D. Benoit et autres
Performance of the EDELWEISS-III experiment for direct dark matter searches, Armengaud, E., Arnaud, Q., Augier, C., Benoît, A., Bergé, L., Bergmann, T., Billard, J., de Boissière, T., Bres, G., Broniatowski, A., Brudanin, V., Camus, P., Cazes, A., Chapellier, M., Charlieux, F., Jésus, …
fr, de, ru, gb
(code pays fourni par la source)
Accès ouvert
2017
article
OpenAlex
Eric Armengaud, Q. Arnaud, C. Augier, A. D. Benoit et autres
fr, de, gb
(code pays fourni par la source)
2016
article
OpenAlex
Q. Arnaud, Eric Armengaud, C. Augier, A. D. Benoit et autres
The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge detectors Fully covered with Inter-Digitized electrodes (FID). They are operated at low fields (< 1 V/cm), and as a consequence charge-carrier trapping significantly affects both the ionization and heat energy measurements. This …
fr, de, gb, ru
(code pays fourni par la source)
Accès ouvert
2016
preprint
OpenAlex
the EDELWEISS Collaboration, Eric Armengaud, Q. Arnaud, C. Augier et autres
We present a measurement of the cosmogenic activation in the germanium cryogenic detectors of the EDELWEISS III direct dark matter search experiment. The decay rates measured in detectors with different exposures to cosmic rays above ground are converted into production rates of …
Accès ouvert
2016
article
OpenAlex
Eric Armengaud, Q. Arnaud, C. Augier, A. Benoît et autres
We present the results of a search for elastic scattering from galactic dark matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30 GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an array of …
fr, ca, de, ru, gb, nl, us
(code pays fourni par la source)