Aller au contenu principal
Profil bibliographique

Daniel Mayani

Informations fournies par OpenAlex. Research Africa ne déduit ni nationalité, ni poste, ni coordonnées personnelles.

58Publications signalées
9450Citations signalées
1Affiliations récentes

Les institutions déclarées

Les domaines associés

Particle physics theoretical and experimental studiesHigh-Energy Particle Collisions ResearchQuantum Chromodynamics and Particle InteractionsDark Matter and Cosmic PhenomenaAtomic and Subatomic Physics Research

Les publications récentes

Accès ouvert 2018 article OpenAlex

Signal yields of keV electronic recoils and their discrimination from nuclear recoils in liquid xenon

Elena Aprile, J. Aalbers, F. Agostini, M. Alfonsi et autres

We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of $92\text{ }\text{ }\mathrm{V}/\mathrm{cm}$, $154\text{ }\text{ }\mathrm{V}/\mathrm{cm}$ and $366\text{ }\text{ }\mathrm{V}/\mathrm{cm}$ using the XENON100 detector. A data-to-simulation fitting …

us, nl, it, de, pt, ae, ch, se, il, fr (code pays fourni par la source)

36 citations Physical review. D/Physical review. D.
Accès ouvert 2018 article OpenAlex

Intrinsic backgrounds from Rn and Kr in the XENON100 experiment

Elena Aprile, J. Aalbers, F. Agostini, M. Alfonsi et autres

In this paper, we describe the XENON100 data analyses used to assess the target-intrinsic background sources radon ( ), thoron ( ) and krypton ( ). We detail the event selections of high-energy alpha particles and decay-specific delayed coincidences. We derive distributions …

us, nl, it, de, pt, ae, ch, se, il, fr (code pays fourni par la source)

23 citations The European Physical Journal C
Accès ouvert 2017 article OpenAlex

Search for bosonic super-WIMP interactions with the XENON100 experiment

Elena Aprile, J. Aalbers, F. Agostini, M. Alfonsi et autres

We present results of searches for vector and pseudoscalar bosonic super-weakly interacting massive particles (WIMPs), which are dark matter candidates with masses at the keV-scale, with the XENON100 experiment. XENON100 is a dual-phase xenon time projection chamber operated at the Laboratori Nazionali …

us, nl, it, de, pt, ae, ch, se, il, fr (code pays fourni par la source)

26 citations Physical review. D/Physical review. D.
Accès ouvert 2017 article OpenAlex

The XENON1T dark matter experiment

Elena Aprile, J. Aalbers, F. Agostini, M. Alfonsi et autres

The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2 t liquid xenon inventory, 2.0 t constitute the active target …

us, nl, it, de, pt, ae, ch, se, il, fr (code pays fourni par la source)

270 citations The European Physical Journal C
Accès ouvert 2017 article OpenAlex

Material radioassay and selection for the XENON1T dark matter experiment

Elena Aprile, J. Aalbers, F. Agostini, M. Alfonsi et autres

The XENON1T dark matter experiment aims to detect weakly interacting massive particles (WIMPs) through low-energy interactions with xenon atoms. To detect such a rare event necessitates the use of radiopure materials to minimize the number of background events within the expected WIMP …

us, nl, it, de, pt, ae, ch, se, il, fr (code pays fourni par la source)

66 citations The European Physical Journal C
Accès ouvert 2017 article OpenAlex

First Dark Matter Search Results from the XENON1T Experiment

Elena Aprile, J. Aalbers, F. Agostini, M. Alfonsi et autres

We report the first dark matter search results from XENON1T, a ∼2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind. The blinded search used 34.2 …

us, nl, it, de, pt, ae, ch, se, il, fr (code pays fourni par la source)

884 citations Physical Review Letters
Accès ouvert 2017 article OpenAlex

Search for magnetic inelastic dark matter with XENON100

Elena Aprile, J. Aalbers, F. Agostini, M. Alfonsi et autres

We present the first search for dark matter-induced delayed coincidence signals in a dual-phase xenon time projection chamber, using the 224.6 live days of the XENON100 science run II. This very distinct signature is predicted in the framework of magnetic inelastic dark …

us, nl, it, de, pt, ae, ch, se, il, fr (code pays fourni par la source)

9 citations Journal of Cosmology and Astroparticle Physics
Accès ouvert 2017 article OpenAlex

Effective field theory search for high-energy nuclear recoils using the XENON100 dark matter detector

Elena Aprile, J. Aalbers, F. Agostini, M. Alfonsi et autres

We report on weakly interacting massive particles (WIMPs) search results in the XENON100 detector using a nonrelativistic effective field theory approach. The data from science run II ($34\text{ }\text{ }\mathrm{kg}\ifmmode\times\else\texttimes\fi{}224.6$ live days) were reanalyzed, with an increased recoil energy interval compared to …

us, nl, it, de, pt, ae, ch, se, il, fr (code pays fourni par la source)

56 citations Physical review. D/Physical review. D.
Accès ouvert 2017 article OpenAlex

Search for WIMP inelastic scattering off xenon nuclei with XENON100

Elena Aprile, J. Aalbers, F. Agostini, M. Alfonsi et autres

We present the first constraints on the spin-dependent, inelastic scattering cross section of weakly interacting massive particles (WIMPs) on nucleons from XENON100 data with an exposure of $7.64\ifmmode\times\else\texttimes\fi{}{10}^{3}\text{ }\text{ }\mathrm{kg}\ifmmode\cdot\else\textperiodcentered\fi{}\text{days}$. XENON100 is a dual-phase xenon time projection chamber with 62 kg of …

us, nl, it, de, pt, ae, ch, se, il, fr (code pays fourni par la source)

60 citations Physical review. D/Physical review. D.
Accès ouvert 2017 article OpenAlex

Online $$^{222}$$ 222 Rn removal by cryogenic distillation in the XENON100 experiment

Elena Aprile, J. Aalbers, F. Agostini, M. Alfonsi et autres

We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column was integrated into the gas purification loop of the XENON100 detector for online radon removal. This enabled us to significantly …

us, nl, it, de, pt, ae, ch, se, il, fr (code pays fourni par la source)

47 citations The European Physical Journal C
Accès ouvert 2017 article OpenAlex

Removing krypton from xenon by cryogenic distillation to the ppq level

Elena Aprile, J. Aalbers, F. Agostini, M. Alfonsi et autres

The XENON1T experiment aims for the direct detection of dark matter in a detector filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. …

us, nl, it, de, pt, ae, ch, se, il, fr (code pays fourni par la source)

73 citations The European Physical Journal C
Accès ouvert 2017 article OpenAlex

Results from a calibration of XENON100 using a source of dissolved radon-220

Elena Aprile, J. Aalbers, F. Agostini, M. Alfonsi et autres

A $^{220}\mathrm{Rn}$ source is deployed on the XENON100 dark matter detector in order to address the challenges in calibration of tonne-scale liquid noble element detectors. We show that the $^{212}\mathrm{Pb}$ beta emission can be used for low-energy electronic recoil calibration in searches …

us, nl, it, de, pt, ae, ch, se, il, fr (code pays fourni par la source)

38 citations Physical review. D/Physical review. D.

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.