{"item": {"cve_id": "CVE-2025-9377", "ghsa_id": "", "osv_id": "", "title": "Authenticated RCE via Parental Control command injection", "description": "The authenticated remote command execution (RCE) vulnerability exists  in the Parental Control page on TP-Link Archer C7(EU) V2 and TL-WR841N/ND(MS) V9.\n\nThis issue affects Archer C7(EU) V2: before 241108 and TL-WR841N/ND(MS) V9: before 241108.\n\nBoth products have reached the status of EOL (end-of-life).\nIt's recommending to \n\npurchase the new \nproduct to ensure better performance and security. If replacement is not\n an option in the short term, please use the second reference link to \ndownload and install the patch(es).", "published_at": "2025-08-29T18:15:43.220", "modified_at": "2026-06-17T10:08:50.390", "vendor": "Tp-link", "product": "tl-wr841n Firmware", "affected_versions": ["0"], "fixed_versions": [], "cvss_score": 7.2, "cvss_version": "3.1", "cvss_vector": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "severity": "HIGH", "epss_score": 0.35823, "epss_percentile": 0.98433, "epss_date": "2026-10-07", "is_kev": true, "kev_date": "2025-09-03", "kev_due_date": "2025-09-24", "kev_action": "Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.", "cwe_ids": ["CWE-78"], "attack_vector": "NETWORK", "attack_complexity": "LOW", "privileges_required": "HIGH", "user_interaction": "NONE", "references": ["https://www.tp-link.com/us/support/faq/4308/", "https://www.tp-link.com/us/support/faq/4365/", "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2025-9377"], "source_urls": {"NVD": "https://nvd.nist.gov/vuln/detail/CVE-2025-9377", "CVE.org": "https://www.cve.org/CVERecord?id=CVE-2025-9377", "CISA": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2025-9377", "FIRST EPSS": "https://api.first.org/data/v1/epss?cve=CVE-2025-9377"}, "patch_available": null, "workaround_available": null, "sources": ["NVD", "CVE.org", "CISA", "FIRST EPSS"], "reference_items": [{"url": "https://www.tp-link.com/us/support/faq/4308/", "tags": ["Product", "patch", "vendor-advisory"], "source": "NVD", "name": ""}, {"url": "https://www.tp-link.com/us/support/faq/4365/", "tags": ["Vendor Advisory", "vendor-advisory"], "source": "NVD", "name": ""}, {"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2025-9377", "tags": ["US Government Resource", "government-resource"], "source": "NVD", "name": ""}], "cvss_v4_score": 8.6, "cvss_v4_vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "cvss_v4_severity": "HIGH", "nvd_status": "Analyzed", "cna": "TPLink", "date_reserved": "2025-08-23T00:15:09.238Z", "ssvc": {"options": {"Exploitation": "active", "Automatable": "no", "Technical Impact": "total"}, "version": "2.0.3", "timestamp": "2025-09-03T03:55:24.199487Z", "role": "CISA Coordinator"}, "affected_products": [{"vendor": "Tp-link", "product": "tl-wr841n Firmware", "ranges": ["avant 241108"], "first_unaffected": ["241108"], "source": "NVD"}, {"vendor": "Tp-link", "product": "tl-wr841nd Firmware", "ranges": ["avant 241108"], "first_unaffected": ["241108"], "source": "NVD"}, {"vendor": "Tp-link", "product": "Archer c7 Firmware", "ranges": ["avant 241108"], "first_unaffected": ["241108"], "source": "NVD"}, {"vendor": "TP-Link Systems Inc.", "product": "Archer C7(EU) V2", "ranges": ["avant 241108"], "first_unaffected": ["241108"], "source": "CVE.org"}, {"vendor": "TP-Link Systems Inc.", "product": "TL-WR841N/ND(MS) V9", "ranges": ["avant 241108"], "first_unaffected": ["241108"], "source": "CVE.org"}], "kev_name": "TP-Link Archer C7(EU) and TL-WR841N/ND(MS) OS Command Injection Vulnerability", "kev_short_description": "TP-Link Archer C7(EU) and TL-WR841N/ND(MS) contain an OS command injection vulnerability that exists in the Parental Control page. The impacted products could be end-of-life (EoL) and/or end-of-service (EoS). Users should discontinue product utilization.", "kev_ransomware": "Unknown", "kev_notes": "https://www.tp-link.com/us/support/faq/4308/ ; https://nvd.nist.gov/vuln/detail/CVE-2025-9377", "kev_cwes": ["CWE-78"], "wordfence_id": "", "mentions_sources": [], "version_match": "unknown", "risk_score": 70, "risk_class": "Critique", "impact": {"confidentialite": "élevé", "integrite": "élevé", "disponibilite": "élevé", "summary": "Un attaquant exploitant cette vulnérabilité pourrait, selon les conditions décrites par les sources, exploitable à distance (réseau), avec des privilèges existants, affecter la confidentialité des données, l'intégrité du système et la disponibilité du service.", "basis": "CVSS 3.1"}, "mechanism": "Injection de commande système : des entrées mal contrôlées peuvent influer sur des commandes exécutées par le serveur.", "mitigation": {"correction": {"available": true, "text": "Mettre à jour : selon les sources, ne sont plus concernées les versions à partir de tl-wr841n Firmware 241108, tl-wr841nd Firmware 241108, Archer c7 Firmware 241108, Archer C7(EU) V2 241108, TL-WR841N/ND(MS) V9 241108."}, "mitigation": {"specific": "Aucune mesure de mitigation spécifique confirmée par les sources consultées. Consultez les références officielles pour d'éventuelles mesures détaillées.", "general": ["Maintenir le produit à jour et activer les mises à jour de sécurité.", "Restreindre l'exposition réseau du service au strict nécessaire.", "Appliquer le principe du moindre privilège.", "Surveiller les journaux et les alertes de sécurité."], "specific_links": []}, "containment": {"applicable": true, "actions": ["Action recommandée par la CISA : Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.", "Isoler ou restreindre l'accès au service concerné.", "Restreindre les flux réseau entrants/sortants liés au composant.", "Renforcer la surveillance des journaux et des accès.", "Désactiver temporairement le composant vulnérable si l'activité le permet."]}, "note": "Priorité aux consignes officielles de l'éditeur et des références. Vérifiez toujours l'avis de sécurité avant toute intervention en production.", "official_links": [{"url": "https://www.tp-link.com/us/support/faq/4308/", "groupe": "correctif", "groupe_titre": "Correctifs et versions corrigées", "editeur": "TP-Link", "domaine": "www.tp-link.com"}, {"url": "https://www.tp-link.com/us/support/faq/4365/", "groupe": "avis_editeur", "groupe_titre": "Avis de sécurité de l'éditeur", "editeur": "TP-Link", "domaine": "www.tp-link.com"}]}, "plain": {"verdict": "now", "verdict_label": "Exploité par des attaquants · à traiter aujourd'hui", "verdict_css": "now", "verdict_rank": 0, "headline": "Un attaquant peut faire exécuter ses propres commandes au serveur", "headline_is_derived": true, "action": "Mettre à jour vers tl-wr841n Firmware 241108, tl-wr841nd Firmware 241108, Archer c7 Firmware 241108 ou plus récent, version publiée comme non concernée.", "action_kind": "update", "concerned": [{"version": "tl-wr841n Firmware 241108, tl-wr841nd Firmware 241108, Archer c7 Firmware 241108 ou plus récent", "state": "safe", "state_label": "Non concerné", "todo": "Rien à faire. Gardez les mises à jour automatiques activées."}, {"version": "0", "state": "hit", "state_label": "Concerné", "todo": "Mettre à jour vers tl-wr841n Firmware 241108, tl-wr841nd Firmware 241108, Archer c7 Firmware 241108 ou plus récent, version publiée comme non concernée."}, {"version": "Je ne connais pas ma version", "state": "unknown", "state_label": "À vérifier", "todo": "La version s'affiche généralement dans le menu « À propos » ou « Aide » du logiciel."}], "steps": [{"title": "Sauvegarder avant d'intervenir", "detail": "Une copie récente des données et de la configuration. Si votre hébergeur propose une sauvegarde en un clic, c'est le moment.", "duration": "10 min", "priority": false}, {"title": "Mettre à jour vers tl-wr841n Firmware 241108, tl-wr841nd Firmware 241108, Archer c7 Firmware 241108 ou plus récent, version publiée comme non concernée", "detail": "C'est la correction officielle. Tant qu'elle n'est pas appliquée, les autres mesures ne sont que temporaires.", "duration": "15 à 45 min", "priority": true}, {"title": "En attendant : réduire l'exposition sur Internet", "detail": "La faille est exploitable à distance. Limiter l'accès au service depuis l'extérieur (pare-feu, filtrage d'adresses, VPN) réduit fortement le risque.", "duration": "30 min", "priority": false}, {"title": "Vérifier que vous n'avez pas déjà été touché", "detail": "Cette faille est activement exploitée. Contrôler les comptes créés récemment, les connexions inhabituelles et les fichiers modifiés depuis la date de publication.", "duration": "30 min", "priority": true}, {"title": "Confirmer que tout fonctionne encore", "detail": "Après correction : page d'accueil, connexion, et les deux ou trois fonctions dont vous vous servez tous les jours.", "duration": "10 min", "priority": false}], "exploited": true, "exploited_label": "Oui, des attaques réelles sont constatées", "fixed_label": "tl-wr841n Firmware 241108, tl-wr841nd Firmware 241108, Archer c7 Firmware 241108 (non concernée selon les sources)", "affected_label": "0"}, "severity_display": "Élevée", "cvss_is_legacy": false, "risk_score_computable": true, "identifier": "CVE-2025-9377", "severity_fr": "Élevée", "epss_pct": 35.8, "source_records": [{"source": "NVD", "label": "NVD, NIST", "date_label": "Publié dans la base", "date": "2025-08-29", "url": "https://nvd.nist.gov/vuln/detail/CVE-2025-9377"}, {"source": "CVE.org", "label": "CVE.org, programme CVE", "date_label": "Publié par l'organisme CNA", "date": "2025-08-29", "url": "https://www.cve.org/CVERecord?id=CVE-2025-9377"}, {"source": "CISA", "label": "CISA KEV", "date_label": "Ajout au catalogue", "date": "2025-09-03", "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2025-9377"}, {"source": "FIRST EPSS", "label": "FIRST EPSS", "date_label": "Score daté du", "date": "2026-10-07", "url": "https://api.first.org/data/v1/epss?cve=CVE-2025-9377"}], "exploit_public": false, "reseau_sans_auth": false, "exposition": "À distance, sous conditions (compte ou action d'un utilisateur)", "owasp": [{"code": "A05", "nom": "Injection", "nom_officiel": "Injection", "slug": "a05-injection", "libelle": "A05:2025 Injection", "url_officielle": "https://top10.owasp.org/2025/A05_2025-Injection/"}]}, "presentation": {"en_bref": [{"question": "Est-elle attaquée ?", "ton": "alerte", "reponse": "Oui, attaques constatées", "source": "Catalogue CISA KEV"}, {"question": "Existe-t-il un correctif ?", "ton": "bon", "reponse": "Oui : 241108", "source": "Versions publiées comme non concernées"}, {"question": "Comment l'attaquer ?", "ton": "neutre", "reponse": "À distance, sous conditions (compte ou action d'un utilisateur)", "source": "Vecteur CVSS publié"}, {"question": "Risque d'exploitation", "ton": "alerte", "reponse": "35,8 % sur 30 jours", "source": "Plus probable que 98 % des failles connues"}], "references": [{"cle": "correctif", "titre": "Correctifs et versions corrigées", "explication": "Les pages que les sources désignent comme correctif ou notes de version.", "items": [{"url": "https://www.tp-link.com/us/support/faq/4308/", "domaine": "www.tp-link.com", "editeur": "TP-Link", "etiquettes": ["Page produit", "Correctif", "Avis de l'éditeur"], "nom": "", "lien": true, "casse": false}]}, {"cle": "avis_editeur", "titre": "Avis de sécurité de l'éditeur", "explication": "La parole de l'éditeur du produit : elle fait foi pour savoir quoi installer.", "items": [{"url": "https://www.tp-link.com/us/support/faq/4365/", "domaine": "www.tp-link.com", "editeur": "TP-Link", "etiquettes": ["Avis de l'éditeur"], "nom": "", "lien": true, "casse": false}]}, {"cle": "avis_tiers", "titre": "Avis d'autorités et d'organismes tiers", "explication": "CERT, agences gouvernementales, bases de vulnérabilités, chercheurs.", "items": [{"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2025-9377", "domaine": "www.cisa.gov", "editeur": "CISA", "etiquettes": ["Ressource gouvernementale américaine", "Ressource gouvernementale"], "nom": "", "lien": true, "casse": false}]}], "liens_correction": [{"url": "https://www.tp-link.com/us/support/faq/4308/", "domaine": "www.tp-link.com", "editeur": "TP-Link", "etiquettes": ["Page produit", "Correctif", "Avis de l'éditeur"], "nom": "", "lien": true, "casse": false, "groupe": "correctif", "groupe_titre": "Correctifs et versions corrigées"}, {"url": "https://www.tp-link.com/us/support/faq/4365/", "domaine": "www.tp-link.com", "editeur": "TP-Link", "etiquettes": ["Avis de l'éditeur"], "nom": "", "lien": true, "casse": false, "groupe": "avis_editeur", "groupe_titre": "Avis de sécurité de l'éditeur"}], "nb_exploits": 0, "cvss": {"version": "3.1", "vecteur": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "metriques": [{"code": "AV", "nom": "Vecteur d'attaque", "valeur": "Réseau (à distance, y compris par Internet)", "brut": "N", "explication": "D'où l'attaquant doit agir."}, {"code": "AC", "nom": "Complexité de l'attaque", "valeur": "Faible", "brut": "L", "explication": "Conditions hors du contrôle de l'attaquant."}, {"code": "PR", "nom": "Privilèges requis", "valeur": "Élevés (compte administrateur)", "brut": "H", "explication": "Droits dont l'attaquant a besoin avant d'attaquer."}, {"code": "UI", "nom": "Interaction de l'utilisateur", "valeur": "Aucune", "brut": "N", "explication": "Une victime doit-elle cliquer ou ouvrir quelque chose ?"}, {"code": "S", "nom": "Portée", "valeur": "Inchangée", "brut": "U", "explication": "L'attaque peut-elle toucher d'autres composants que celui qui est vulnérable ?"}, {"code": "C", "nom": "Confidentialité", "valeur": "Élevé", "brut": "H", "explication": "Accès à des informations protégées."}, {"code": "I", "nom": "Intégrité", "valeur": "Élevé", "brut": "H", "explication": "Modification de données ou du système."}, {"code": "A", "nom": "Disponibilité", "valeur": "Élevé", "brut": "H", "explication": "Arrêt ou ralentissement du service."}], "calculateur": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "specification": "https://www.first.org/cvss/v3.1/specification-document"}, "cvss4": {"version": "4.0", "vecteur": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "metriques": [{"code": "AV", "nom": "Vecteur d'attaque", "valeur": "Réseau (à distance, y compris par Internet)", "brut": "N", "explication": "D'où l'attaquant doit agir."}, {"code": "AC", "nom": "Complexité de l'attaque", "valeur": "Faible", "brut": "L", "explication": "Conditions hors du contrôle de l'attaquant."}, {"code": "AT", "nom": "Conditions d'attaque", "valeur": "Aucune", "brut": "N", "explication": "Conditions de déploiement nécessaires à l'attaque."}, {"code": "PR", "nom": "Privilèges requis", "valeur": "Élevés (compte administrateur)", "brut": "H", "explication": "Droits dont l'attaquant a besoin avant d'attaquer."}, {"code": "UI", "nom": "Interaction de l'utilisateur", "valeur": "Aucune", "brut": "N", "explication": "Une victime doit-elle agir ?"}, {"code": "VC", "nom": "Confidentialité du système vulnérable", "valeur": "Élevé", "brut": "H", "explication": ""}, {"code": "VI", "nom": "Intégrité du système vulnérable", "valeur": "Élevé", "brut": "H", "explication": ""}, {"code": "VA", "nom": "Disponibilité du système vulnérable", "valeur": "Élevé", "brut": "H", "explication": ""}, {"code": "SC", "nom": "Confidentialité des systèmes suivants", "valeur": "Aucun", "brut": "N", "explication": "Systèmes touchés par rebond."}, {"code": "SI", "nom": "Intégrité des systèmes suivants", "valeur": "Aucun", "brut": "N", "explication": "Systèmes touchés par rebond."}, {"code": "SA", "nom": "Disponibilité des systèmes suivants", "valeur": "Aucun", "brut": "N", "explication": "Systèmes touchés par rebond."}], "calculateur": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "specification": "https://www.first.org/cvss/v4.0/specification-document"}, "cwe": [{"id": "CWE-78", "nom": "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')", "url": "https://cwe.mitre.org/data/definitions/78.html"}], "owasp": [{"code": "A05", "nom": "Injection", "nom_officiel": "Injection", "slug": "a05-injection", "libelle": "A05:2025 Injection", "url_officielle": "https://top10.owasp.org/2025/A05_2025-Injection/"}], "ssvc": {"lignes": [{"nom": "Exploitation", "valeur": "Exploitation active constatée", "brut": "active"}, {"nom": "Automatisable", "valeur": "Non : l'attaque ne peut pas être entièrement automatisée", "brut": "no"}, {"nom": "Impact technique", "valeur": "Total : contrôle complet du composant ou de ses informations", "brut": "total"}], "version": "2.0.3", "date": "2025-09-03", "role": "CISA Coordinator", "url": "https://www.cisa.gov/stakeholder-specific-vulnerability-categorization-ssvc"}, "chronologie": [{"date": "2025-08-23", "libelle": "Identifiant réservé", "qui": "Programme CVE"}, {"date": "2025-08-29", "libelle": "Publication de la vulnérabilité", "qui": "TPLink"}, {"date": "2025-09-03", "libelle": "Ajout au catalogue des failles exploitées", "qui": "CISA"}, {"date": "2025-09-03", "libelle": "Décision SSVC publiée", "qui": "CISA"}, {"date": "2025-09-24", "libelle": "Échéance de correction fixée par la CISA", "qui": "CISA"}, {"date": "2026-06-17", "libelle": "Dernière mise à jour de la fiche source", "qui": "Source"}, {"date": "2026-10-07", "libelle": "Calcul du score EPSS affiché", "qui": "FIRST"}], "liens_officiels": [{"nom": "NVD (NIST)", "url": "https://nvd.nist.gov/vuln/detail/CVE-2025-9377", "description": "Fiche de référence : CVSS, CPE, références étiquetées."}, {"nom": "CVE.org", "url": "https://www.cve.org/CVERecord?id=CVE-2025-9377", "description": "Enregistrement officiel publié par l'organisme qui a attribué l'identifiant."}, {"nom": "CISA KEV", "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2025-9377", "description": "Entrée du catalogue des failles activement exploitées."}, {"nom": "FIRST EPSS", "url": "https://api.first.org/data/v1/epss?cve=CVE-2025-9377", "description": "Score de probabilité d'exploitation du jour."}, {"nom": "OSV.dev", "url": "https://osv.dev/vulnerability/CVE-2025-9377", "description": "Paquets open source concernés et versions corrigées."}, {"nom": "GitHub Advisory Database", "url": "https://github.com/advisories?query=CVE-2025-9377", "description": "Avis de sécurité des dépendances logicielles."}], "produits": [{"vendor": "Tp-link", "product": "tl-wr841n Firmware", "ranges": ["avant 241108"], "first_unaffected": ["241108"], "source": "NVD"}, {"vendor": "Tp-link", "product": "tl-wr841nd Firmware", "ranges": ["avant 241108"], "first_unaffected": ["241108"], "source": "NVD"}, {"vendor": "Tp-link", "product": "Archer c7 Firmware", "ranges": ["avant 241108"], "first_unaffected": ["241108"], "source": "NVD"}, {"vendor": "TP-Link Systems Inc.", "product": "Archer C7(EU) V2", "ranges": ["avant 241108"], "first_unaffected": ["241108"], "source": "CVE.org"}, {"vendor": "TP-Link Systems Inc.", "product": "TL-WR841N/ND(MS) V9", "ranges": ["avant 241108"], "first_unaffected": ["241108"], "source": "CVE.org"}], "notes_kev": ["https://www.tp-link.com/us/support/faq/4308/", "https://nvd.nist.gov/vuln/detail/CVE-2025-9377"]}, "consulted_at": "2026-10-07T20:57:07.874131+00:00"}